MPCB - I

Pioneers in the industry, we offer schneider gv3p32 tesys deca manual starter and protector thermal magnetic circuit protector rotary, schneider gv2mc02 tesys gv2 surface mount enclosure for tesys gv2me ip55 rated, schneider gv5p150h motor circuit breaker tesys gv5 3p 150a icu 70ka thermal magnetic, schneider gv2l10 tesys deca manual starter and protector magnetic circuit protector rotary handle 6, schneider gv2apn01 extended rotary handle kit tesys gv2 ip54 black handle with trip indication for and schneider gv2me01 tesys deca manual starter and protector thermal magnetic circuit protector push b from India.

Schneider GV3P32 Tesys Deca Manual Starter And Protector Thermal Magnetic Circuit Protector Rotary

Request Callback

₹ 14436 / Piece Get Latest Price

Product Brochure
SeriesGV3
Setting Range23-32A
PhaseThree Phase
Mounting TypeDIN Rail
Trip ClassClass 10
Breaking Capacity50 kA
Auxiliary ContactsNo Aux
Control Voltage415 V AC
ApplicationFan Motor
Model No.GV3P32
BrandSchneider
Device applicationMotor protection
Network frequency50/60 Hz conforming to IEC 60947-2
Trip unit technologyThermal-magnetic
TeSys GV motor circuit breaker, 3 poles (3P), 32A/690V, for 3-phase motor applications 15kW@400V. It provides a thermal-magnetic protection with a thermal setting range 23-32A, magnetic tripping at 14xIn, high breaking capacity Icu 100kA@400V. Connection by Everlink BTR screw terminals. Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).

Schneider GV2MC02 Tesys Gv2 Surface Mount Enclosure For Tesys Gv2Me Ip55 Rated

Request Callback

₹ 2458 / Piece Get Latest Price

Product Brochure
MaterialMild Steel (MS)
Setting Range0.16–0.25 A
Number of DoorsSingle Door
Rated Operational Current2.5 A
Size (W x H x D)300x300x150 mm
PhaseThree Phase
Mounting TypeBase Mount
Trip ClassClass 10
Breaking Capacity25 kA
Control Voltage24 V AC
Auxiliary ContactsNo Aux
TeSys enclosed starters, empty enclosure, for thermal magnetic circuit breakers GV2ME. Surface mounting enclosure with screw fixing, 2 knock-outs for cable glands on top and bottom, sealable cover. Polycarbonate enclosure, double insulated with protective conductor, IP55 protection. To be equipped with a motor circuit breaker GV2ME, and start-emergency stop buttons GV2K (to be ordered separately). Possible mounting of 1 side auxiliary contact blocks GVAD, GVAM, GVAD on both sides of GV2ME (to be ordered separately). It conforms to IEC 60947-2 and IEC 60947-4-1, Green Premium compliant (RoHS/REACh).

Schneider GV5P150H Motor Circuit Breaker Tesys Gv5 3P 150A Icu 70Ka Thermal Magnetic

Request Callback

₹ 44094 / Piece Get Latest Price

Product Brochure
Setting Range4–6.3 A
Rated Operational Current70A
PhaseThree Phase
Breaking Capacity50 kA
Control Voltage415 V AC
Auxiliary Contacts1NO+1NC
StandardsIS/IEC 60947-4
TeSys GV motor circuit breaker, 3 poles (3P), 150A/690V, for protection of 3-phase motors 55-75kW@400V. It provides thermal magnetic protection and additional protections, breaking capacity Icu 70kA, start-stop control by rotary handle, connection for bars or cables with lugs (direct connection of cables with additional connectors). Thermal protection adjustable by dials with a setting current Ir in range 70-150A and a selectable tripping class 5, 10 or 20, magnetic protection at 15 In. Additional protections with fixed pick-up include short time delay protection Isd at 13 Ir, phase unbalance and loss protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh). 

Schneider GV2L10 Tesys Deca Manual Starter And Protector Magnetic Circuit Protector Rotary Handle 6

Request Callback

₹ 2506 / Piece Get Latest Price

Product Brochure
Starter TypeMANNUAL MOTOR STARTER
Motor Power2 HP
Rated Voltage415 V
Motor PhaseThree Phase
Current Rating6 A
ApplicationConveyor
EnclosureIP65
Control Voltage230 V AC
BrandSiemens
MODEL NUMBERGV2L10
TeSys GV motor circuit breaker, 3 poles (3P), 6.3A/690V, for 3-phase motor applications 2.2kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD010 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine).

Schneider GV2APN01 Extended Rotary Handle Kit Tesys Gv2 Ip54 Black Handle With Trip Indication For

Request Callback

₹ 2373 / Piece Get Latest Price

Product Brochure
Model NoGV2APN01
BrandSchneider
Product or component typeRotary handle kit
Handle colourBlack
RangeTesys
IP degree of protectionIP54
Device Short NameGV2AP
TeSys GV extended rotary handle, for motor circuit breakers GV2L, GV2P mounted inside an enclosure and to be operated externally. For main switch usage, it provides a black handle on grey front plate with indication of 3 positions OFF, ON, TRIP. To be mounted on the door of the enclosure, the handle mechanism ensures an IP54 protection to the mounting. It also includes a mounting adaptor to be screwed on the face of the circuit breaker, and an extension shaft to be be adjusted in length (distance between the door and the back of the circuit breaker must be in range 146-256mm). Padlockable in OFF or ON position with up to 3 padlocks (to be ordered separately). Locking in ON position does not prevent the circuit breaker from tripping (unlocking is required for fault reset). Green Premium compliant (RoHS/REACh).

Schneider GV2ME01 Tesys Deca Manual Starter And Protector Thermal Magnetic Circuit Protector Push B

Request Callback

₹ 2266 / Piece Get Latest Price

Product Brochure
SeriesGV2
Setting Range2.5–4 A
PhaseThree Phase
Mounting TypePanel Mount
Breaking Capacity50 kA
Control Voltage415 V AC
ApplicationCompressor
StandardsIS/IEC 60947-4
BRANDSCHNEIDER
MODEL NUMBERGV2ME01
TeSys GV motor circuit breaker, 3 poles (3P), 0.16A/690V, for 3-phase motor applications less than 0.06kW@400V. It provides a thermal-magnetic protection with a thermal setting range 0.1-0.16A, magnetic tripping at 9xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by push-button guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Schneider GV2ME22 Tesys Deca Manual Starter And Protector Thermal Magnetic Circuit Protector Push B

Request Callback

₹ 3287 / Piece Get Latest Price

Product Brochure
SeriesGV2
Setting Range2.5–4 A
PhaseThree Phase
Breaking Capacity50 kA
Auxiliary Contacts1NO+1NC
Control Voltage230 V AC
ApplicationCompressor
StandardsIS/IEC 60947-4
brandschneider
The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit. The basic motor starter GV2ME controls motors with full load currents up to 32 A. The manual starter is three pole with horsepower ratings. The manual starter is operated by push buttons. The Class 10 ambient compensated thermal over current is adjustable from 20 ampere to 25 ampere. This device has screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Schneider GV4LUG Tesys Gv4 Lug Connectors With Screws 3P

Request Callback

₹ 2253 / Piece Get Latest Price

Product Brochure
SeriesGV4
Setting Range2…115 A
PhaseSingle Phase
Mounting TypeBase Plate
TeSys GV lug connector with screws, for motor circuit breakers GV4. Tu put in place of an EverLink connector, it is used to allow connection of cables with lugs. A terminal shield LAD96590 can complete the lug connections for protection agianst direct contact. Green Premium compliant (RoHS/REACh).

Schneider GZ1LE20 Motor Circuit BreakerEasy Tesys PowerGz1Le3PPushBotton18AMagnetic Trip

Request Callback

₹ 1363 / Piece Get Latest Price

Product Brochure
Breaker TypeMCCB
Rated Current16 A
Poles3 Pole
SeriesTESYS
Breaking Capacity25 kA
StandardsIEC 60947
BRANDSchneider
GZ1LE are 3 poles (3P) magnetic circuit breakers specifically designed for motor protection, conforming to standards IEC 60947-2 and IEC 60947-4-1. Magnetic protection rating is 18A with magnetic trip unit. It provides IP41 in GV2MC01 enclosure and IP55 in GV2MC02 enclosure. It procures standard reliability and 0.1M cycles electrical/mechanical durability. These circuit breakers are designed for connection by screw clamp terminals. Multi-standards certified (IEC, CCC, EAC) and Environmental compliant (RoHs/Reach).

Schneider GV2P04 Tesys Deca Manual Starter And Protector Thermal Magnetic Circuit Protector Rotary

Request Callback

₹ 2542 / Piece Get Latest Price

Product Brochure
SeriesGV2
Setting Range2.5–4 A
PhaseThree Phase
Mounting TypePanel Mount
Breaking Capacity50 kA
Auxiliary Contacts1NO+1NC
Control Voltage230 V AC
StandardsIS/IEC 60947-4
brandschneider
TeSys GV motor circuit breaker, 3 poles (3P), 0.63A/690V, for 3-phase motor applications 0.12-0.18kW@400V. It provides a thermal-magnetic protection with a thermal setting range 0.4-0.63A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by rotary knob guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Schneider GV2P02 Tesys Deca Manual Starter And Protector Thermal Magnetic Circuit Protector Rotary

Request Callback

₹ 2218 / Piece Get Latest Price

SeriesGV2
Setting Range0.16–0.25 A
PhaseThree Phase
Breaking Capacity100 kA
Control Voltage415 V AC
Model NoGV2P02
BrandSchneider
TeSys GV motor circuit breaker, 3 poles (3P), 0.25A/690V, for 3-phase motor applications 0.06kW@400V. It provides a thermal-magnetic protection with a thermal setting range 0.16-0.25A, magnetic tripping at 9xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by rotary knob guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).

Schneider GZ1LE04 - Motor circuit breaker,Easy TeSys Power,GZ1LE,3P,0.63A,magnetic trip

Request Callback

₹ 1261 / Piece Get Latest Price

SeriesTeSys
Setting Range0.63A
Mounting TypeDIN Rail
Breaking Capacity100 kA
Model NoGZ1LE04
BrandSchneider
GZ1LE are 3 pole (3P) magnetic circuit breakers specifically designed for motor protection, conforming to standards IEC 60947-2 and IEC 60947-4-1. Magnetic protection rating is 0.63A with magnetic trip unit. It provides IP41 in GV2MC01 enclosure and IP55 in GV2MC02 enclosure. It procures standard reliability and 0.1M cycles electrical/mechanical durability. These circuit breakers are designed for connection by screw clamp terminals. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

Schneider GV6P320H - Motor circuit breaker, TeSys GV6, 3P, 320A, Icu 70kA, thermal magnetic

Request Callback

₹ 54471 / Piece Get Latest Price

SeriesTeSys
Breaker TypeMCCB
Setting Range0.63–1 A
Rated Current320 A
PhaseSingle Phase
Poles3 Pole
Breaking Capacity70 kA
Rated Voltage690 V
Model NoGV6P320H
BrandSchneider
Device short nameGV6P
TeSys GV motor circuit breaker, 3 poles (3P), 320A/690V, for protection of 3-phase motors 132-160kW@400V. It provides thermal magnetic protection and additional protections, breaking capacity Icu 70kA, start-stop control by rotary handle, connection for bars or cables with lugs (direct connection of cables with additional connectors). Thermal protection adjustable by dials with a setting current Ir in range 160-320A and a selectable tripping class 5, 10 or 20, magnetic protection at 15 In. Additional protections with fixed pick-up include short time delay protection Isd at 13 Ir, phase unbalance and loss protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GZ1LE04 Motor Circuit BreakerEasy Tesys PowerGz1Le3P0.63AMagnetic Trip

Request Callback

₹ 1262 / Piece Get Latest Price

SeriesTeSys
Setting Range0.63
Mounting TypeDIN Rail
Breaking Capacity100 kA
Model NoGZ1LE04
BrandSchneider
GZ1LE are 3 pole (3P) magnetic circuit breakers specifically designed for motor protection, conforming to standards IEC 60947-2 and IEC 60947-4-1. Magnetic protection rating is 0.63A with magnetic trip unit. It provides IP41 in GV2MC01 enclosure and IP55 in GV2MC02 enclosure. It procures standard reliability and 0.1M cycles electrical/mechanical durability. These circuit breakers are designed for connection by screw clamp terminals. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

Schneider GZ1LE10 Motor Circuit BreakerEasy Tesys PowerGz1Le3PPushBotton6.3AMagnetic Trip

Request Callback

₹ 1262 / Piece Get Latest Price

Setting Range6.3 A
SeriesTeSys
Breaking Capacity100 kA
Mounting TypeDIN Rail
Model NoGZ1LE10
BrandSchneider
GZ1LE are 3 pole (3P) magnetic circuit breakers specifically designed for motor protection, conforming to standards IEC 60947-2 and IEC 60947-4-1. Magnetic protection rating is 6.3A with magnetic trip unit. It provides IP41 in GV2MC01 enclosure and IP55 in GV2MC02 enclosure. It procures standard reliability and 0.1M cycles electrical/mechanical durability. These circuit breakers are designed for connection by screw clamp terminals. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

Schneider GZ1LE06 Motor Circuit BreakerEasy Tesys PowerGz1Le3PPushBotton1.6AMagnetic Trip

Request Callback

₹ 1262 / Piece Get Latest Price

SeriesTeSys
Setting Range1.6 A
Mounting TypeDIN Rail
Breaking Capacity100 kA
Model NoGZ1LE06
BrandSchneider
GZ1LE are 3 pole (3P) magnetic circuit breakers specifically designed for motor protection, conforming to standards IEC 60947-2 and IEC 60947-4-1. Magnetic protection rating is 1.6A with magnetic trip unit. It provides IP41 in GV2MC01 enclosure and IP55 in GV2MC02 enclosure. It procures standard reliability and 0.1M cycles electrical/mechanical durability. These circuit breakers are designed for connection by screw clamp terminals. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

Schneider GZ1LE03 - Motor circuit breaker,Easy TeSys Power,GZ1LE,3P,0.40A,magnetic trip

Request Callback

₹ 1261 / Piece Get Latest Price

SeriesTeSys
Setting Range0.40A
Mounting TypeDIN Rail
Breaking Capacity100 kA
Model NoGZ1LE03
BrandSchneider
GZ1LE are 3 pole (3P) magnetic circuit breakers specifically designed for motor protection, conforming to standards IEC 60947-2 and IEC 60947-4-1. Magnetic protection rating is 0.4A with magnetic trip unit. It provides IP41 in GV2MC01 enclosure and IP55 in GV2MC02 enclosure. It procures standard reliability and 0.1M cycles electrical/mechanical durability. These circuit breakers are designed for connection by screw clamp terminals. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

Schneider GZ1LE05 Motor Circuit BreakerEasy Tesys PowerGz1Le3PPushBotton1AMagnetic Trip

Request Callback

₹ 1262 / Piece Get Latest Price

SeriesTeSys
Setting Range1 A
Mounting TypeDIN Rail
Breaking Capacity100 kA
Model NoGZ1LE05
BrandSchneider
GZ1LE are 3 poles (3P) magnetic circuit breakers specifically designed for motor protection, conforming to standards IEC 60947-2 and IEC 60947-4-1. Magnetic protection rating is 1A with magnetic trip unit. It provides IP41 in GV2MC01 enclosure and IP55 in GV2MC02 enclosure. It procures standard reliability and 0.1M cycles electrical/mechanical durability. These circuit breakers are designed for connection by screw clamp terminals. Multi-standards certified (IEC, CCC, EAC) and Environmental compliant (RoHs/Reach).

Schneider GZ1LE05 - Motor circuit breaker,Easy TeSys Power,GZ1LE,3P,push-botton,1A,magnetic trip

Request Callback

₹ 1262 / Piece Get Latest Price

SeriesTeSys
Setting Range1A
PhaseThree Phase
Mounting TypeDIN Rail
Breaking Capacity100 kA
Model NoGZ1LE05
BrandSchneider
GZ1LE are 3 poles (3P) magnetic circuit breakers specifically designed for motor protection, conforming to standards IEC 60947-2 and IEC 60947-4-1. Magnetic protection rating is 1A with magnetic trip unit. It provides IP41 in GV2MC01 enclosure and IP55 in GV2MC02 enclosure. It procures standard reliability and 0.1M cycles electrical/mechanical durability. These circuit breakers are designed for connection by screw clamp terminals. Multi-standards certified (IEC, CCC, EAC) and Environmental compliant (RoHs/Reach).

Schneider GZ1LE16 Motor Circuit BreakerEasy Tesys PowerGz1Le3PPushBotton14AMagnetic Trip

Request Callback

₹ 1363 / Piece Get Latest Price

SeriesTeSys
Setting Range14A
Mounting TypeDIN Rail
Breaking Capacity100 kA
Model NoGZ1LE16
BrandSchneider
GZ1LE are 3 pole (3P) magnetic circuit breakers specifically designed for motor protection, conforming to standards IEC 60947-2 and IEC 60947-4-1. Magnetic protection rating is 14A with magnetic trip unit. It provides IP41 in GV2MC01 enclosure and IP55 in GV2MC02 enclosure. It procures standard reliability and 0.1M cycles electrical/mechanical durability. These circuit breakers are designed for connection by screw clamp terminals. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

Schneider GZ1LE14 Motor Circuit BreakerEasy Tesys PowerGz1Le3PPushBotton10AMagnetic Trip

Request Callback

₹ 1262 / Piece Get Latest Price

SeriesTeSys
Setting Range10A
Mounting TypeDIN Rail
Breaking Capacity100 kA
Model NoGZ1LE14
BrandSchneider
GZ1LE are 3 pole (3P) magnetic circuit breakers specifically designed for motor protection, conforming to standards IEC 60947-2 and IEC 60947-4-1. Magnetic protection rating is 10A with magnetic trip unit. It provides IP41 in GV2MC01 enclosure and IP55 in GV2MC02 enclosure. It procures standard reliability and 0.1M cycles electrical/mechanical durability. These circuit breakers are designed for connection by screw clamp terminals. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

Schneider GV5P220H - Motor circuit breaker, TeSys GV5, 3P, 220A, Icu 70kA, thermal magnetic

Request Callback

₹ 42356 / Piece Get Latest Price

Breaker TypeMCCB
Rated Current220 A
Poles3 Pole
SeriesTesys
Breaking Capacity70 kA
Rated Voltage690 V
Model NoGV5P220H
BrandSchneider
TeSys GV motor circuit breaker, 3 poles (3P), 220A/690V, for protection of 3-phase motors 90-110kW@400V. It provides thermal magnetic protection and additional protections, breaking capacity Icu 70kA, start-stop control by rotary handle, connection for bars or cables with lugs (direct connection of cables with additional connectors). Thermal protection adjustable by dials with a setting current Ir in range 100-220A and a selectable tripping class 5, 10 or 20, magnetic protection at 15 In. Additional protections with fixed pick-up include short time delay protection Isd at 13 Ir, phase unbalance and loss protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GZ1LE08 Motor Circuit BreakerEasy Tesys PowerGz1Le3PPushBotton4AMagnetic Trip

Request Callback

₹ 1262 / Piece Get Latest Price

SeriesTeSys
Setting Range4 A
Mounting TypeDIN Rail
Breaking Capacity100 kA
Model NoGZ1LE08
BrandSchneider
GZ1LE are 3 pole (3P) magnetic circuit breakers specifically designed for motor protection, conforming to standards IEC 60947-2 and IEC 60947-4-1. Magnetic protection rating is 4A with magnetic trip unit. It provides IP41 in GV2MC01 enclosure and IP55 in GV2MC02 enclosure. It procures standard reliability and 0.1M cycles electrical/mechanical durability. These circuit breakers are designed for connection by screw clamp terminals. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).

Schneider GVAD0110 - TeSys GV2 & GV3 - auxiliary contact - 1 NO + 1 NC (fault)

Request Callback

₹ 3853 / Piece Get Latest Price

BrandSchneider Electric
Contact Configuration1NO + 1NC
Compatible Contactor SeriesTeSys
Model NoGVAD0110
Device short nameGVAD
RangeTeSys TeSys Deca
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NC fault signaling contact + 1NO instantaneous auxiliary contact. Instantaneous auxiliary contact rated for operation up to 6A/690V AC and 6A/240V DC. Fault signaling contact rated for operation up to 2A/240V AC and 1A/60V DC. To be installed on left-hand side of the circuit breaker (1 block mounting maximum), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider GVAN11 ManStarter Short Cir Contact 575Vac 1

Request Callback

₹ 1005 / Piece Get Latest Price

BrandSchneider Electric
Contact Configuration1NO + 1NC
Compatible Contactor SeriesTeSys
Model NoGVAN11
Device short nameGVAN
Product or component typeAuxiliary contact block
Protection typeGB2CB... circuit breaker GG fuse 10 A
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NO+1NC instantaneous auxiliary contacts. Rated for operation up to 6A/690V AC and 6A/240V DC. To be installed on left-hand side of the circuit breaker (2 blocks mounting possible), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider GVAE20 Tesys Gv2 & Gv3 Auxiliary Contact 2 No

Request Callback

₹ 920 / Piece Get Latest Price

ApplicationSelector Switch
Contact Configuration2NO
Rated Current2.5 A
Terminal TypeScrew
Model NoGVAE20
BrandSchneider
Product or component typeAuxiliary contact block
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 2NO instantaneous auxiliary contacts. Rated for operation up to 2A/240V AC and 1A/60V DC. To be installed on front side of the circuit breaker, connection by screw clamp terminals. Sold in lots of 10 units. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider GVAN20 Tesys Gv2 & Gv3 Auxiliary Contact Block 2 No

Request Callback

₹ 1005 / Piece Get Latest Price

ApplicationSelector Switch
Contact Configuration2NO
Rated Current6 A
Rated Voltage690 V
Terminal TypeScrew
Model NoGVAN20
BrandSchneider
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 2NO instantaneous auxiliary contacts. Rated for operation up to 6A/690V AC and 6A/240V DC. To be installed on left-hand side of the circuit breaker (2 blocks mounting possible), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Schneider GV2LE20 Tesys Gv2 Manual Starter And Protector Magnetic Circuit Protector Toggle Switch 1

Request Callback

₹ 2536 / Piece Get Latest Price

SeriesGV2
Setting Range18 A
PhaseThree Phase
Breaking Capacity15 kA
Control Voltage415 V AC
Model NoGV2LE20
BrandSchneider
TeSys GV motor circuit breaker, 3 poles (3P), 18A/690V, for 3-phase motor applications 7.5kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 15kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD21 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV2L05 Tesys Deca Manual Starter And Protector Magnetic Circuit Protector Rotary Handle 1

Request Callback

₹ 2506 / Piece Get Latest Price

SeriesTeSys Deca
Setting Range1 A
PhaseThree Phase
Breaking Capacity100 kA
Control Voltage415 V AC
Model NoGV2L05
BrandSchneider
Product or component typeMotor circuit breaker
TeSys GV motor circuit breaker, 3 poles (3P), 1A/690V, for 3-phase motor applications 0.25-0.37kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD05 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV2L06 Tesys Deca Manual Starter And Protector Magnetic Circuit Protector Rotary Handle 1

Request Callback

₹ 2506 / Piece Get Latest Price

SeriesTeSys Deca
Setting Range1.6 A
PhaseThree Phase
Breaking Capacity100 kA
Control Voltage415 V AC
Model NoGV2L06
BrandSchneider
Product or component typeMotor circuit breaker
TeSys GV motor circuit breaker, 3 poles (3P), 1.6A/690V, for 3-phase motor applications 0.55kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD06 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV2L08 Tesys Deca Manual Starter And Protector Magnetic Circuit Protector Rotary Handle 4

Request Callback

₹ 2506 / Piece Get Latest Price

SeriesTeSys Deca
Setting Range4 A
PhaseThree Phase
Breaking Capacity100 kA
Control Voltage415 V AC
Model NoGV2L08
BrandSchneider
TeSys GV motor circuit breaker, 3 poles (3P), 4A/690V, for 3-phase motor applications 1.1-1.5kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD08 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV2L32 Tesys Deca Manual Starter And Protector Magnetic Circuit Protector Rotary Handle 3

Request Callback

₹ 2506 / Piece Get Latest Price

SeriesTeSys Deca
Setting Range32 A
PhaseThree Phase
Breaking Capacity50 kA
Control Voltage415 V AC
Model NoGV2L32
BrandSchneider
TeSys GV motor circuit breaker, 3 poles (3P), 32A/690V, for 3-phase motor applications 15kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 50kA@400V. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD32 (to be ordered separately). Multi standards certified (IEC, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV2L20 Tesys Deca Manual Starter And Protector Magnetic Circuit Protector Rotary Handle 1

Request Callback

₹ 2506 / Piece Get Latest Price

SeriesTeSys Deca
Setting Range18 A
PhaseThree Phase
Breaking Capacity50 kA
Control Voltage415 V AC
Model NoGV2L20
BrandSchneider
TeSys GV motor circuit breaker, 3 poles (3P), 18A/690V, for 3-phase motor applications 7.5kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 50kA@400V. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD21 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV2L14 Tesys Deca Manual Starter And Protector Magnetic Circuit Protector Rotary Handle 1

Request Callback

₹ 2506 / Piece Get Latest Price

SeriesTeSys Deca
Setting Range10 kA
PhaseThree Phase
Breaking Capacity100 kA
Control Voltage415 V AC
Model NoGV2L14
BrandSchneider
Product or component typeMotor circuit breaker
TeSys GV motor circuit breaker, 3 poles (3P), 10A/690V, for 3-phase motor applications 3-4kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD14 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV2LE04 Tesys Gv2 Manual Starter And Protector Magnetic Circuit Protector Toggle Switch 0

Request Callback

₹ 2183 / Piece Get Latest Price

SeriesGV2
Setting Range0.63 A
PhaseThree Phase
Breaking Capacity100 kA
Control Voltage415 V AC
Model NoGV2LE04
BrandSchneider
TeSys GV motor circuit breaker, 3 poles (3P), 0.63A/690V, for 3-phase motor applications 0.12-0.18kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD04 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV2LE07 Tesys Gv2 Manual Starter And Protector Magnetic Circuit Protector Toggle Switch 2

Request Callback

₹ 2183 / Piece Get Latest Price

SeriesGV2
Setting Range2.5 A
PhaseThree Phase
Breaking Capacity100 kA
Control Voltage415 V AC
Model NoGV2LE07
BrandSchneider
TeSys GV motor circuit breaker, 3 poles (3P), 2.5A/690V, for 3-phase motor applications 0.75kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD07 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV2LE08 Tesys Gv2 Manual Starter And Protector Magnetic Circuit Protector Toggle Switch 4

Request Callback

₹ 2183 / Piece Get Latest Price

SeriesGV2
Setting Range4 A
PhaseThree Phase
Breaking Capacity100 kA
Control Voltage415 V AC
Model NoGV2LE08
BrandSchneider
TeSys GV motor circuit breaker, 3 poles (3P), 4A/690V, for 3-phase motor applications 1.1-1.5kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD08 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV2LE16 Tesys Gv2 Manual Starter And Protector Magnetic Circuit Protector Toggle Switch 1

Request Callback

₹ 2183 / Piece Get Latest Price

SeriesTeSys Deca
Setting Range14 A
PhaseThree Phase
Breaking Capacity15 kA
Control Voltage415 V AC
Model NoGV2LE16
BrandSchneider
TeSys GV motor circuit breaker, 3 poles (3P), 14A/690V, for 3-phase motor applications 5.5kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 15kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD16 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV2L22 Tesys Deca Manual Starter And Protector Magnetic Circuit Protector Rotary Handle 2

Request Callback

₹ 2506 / Piece Get Latest Price

SeriesTeSys Deca
Setting Range25 A
PhaseThree Phase
Breaking Capacity50 kA
Control Voltage415 V AC
Model NoGV2L22
BrandSchneider
TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for 3-phase motor applications 11kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 50kA@400V. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD22 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Schneider GV2L03 Tesys Deca Manual Starter And Protector Magnetic Circuit Protector Rotary Handle 0

Request Callback

₹ 2506 / Piece Get Latest Price

SeriesTeSys Deca
Setting Range0.4 A
PhaseThree Phase
Breaking Capacity100 kA
Control Voltage415 V AC
Model NoGV2L03
BrandSchneider
TeSys GV motor circuit breaker, 3 poles (3P), 0.4A/690V, for 3-phase motor applications 0.06-0.09kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA. Connection by screw clamp terminals. Start-stop control by rotary handle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD03 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
X

Contact Us

Govind Chauhan (Managing Director)
Electrosync Automation India Private Limited
1st Floor, 535, Patparganj Industrial Area
New Delhi - 110092, Delhi, India

Send Email
Share: