Overload Relay - I

We are a leading of schneider laeb3 terminal blockeasy tesys protectfor lre322e365, schneider lrd12 thermal overload relay tesys lrd 5.5...8 a class 10a, schneider lr2k0302 tesys k overload relay cl10 0.16 0.23a, schneider la9g3614 spreaders 3p g630800 80mm connection, schneider lr2k0301 tesys k overload relay cl10 0.11 0.16a and schneider lrd03 tesys lrd thermal overload relays 0.25...0.4 a class 10a from New Delhi, India.

Schneider LAEB3 Terminal BlockEasy Tesys ProtectFor Lre322E365

Request Callback

₹ 1028 / Piece Get Latest Price

Product Brochure
TypeMotor
Connection TypeScrewless
Cable Size0.14–1.5 mm²
Rated Current6 A
Rated Voltage110 V
Mounting TypePCB Mount
Number Of Poles1 pole
Housing MaterialPVC
ColorBlack
EasyPact TVS terminal block for mounting on LRE322-E365 thermal overload relays. To be used for a separate mounting of overload relay and contactor. It provides top connections by screw clamp terminals, clip-on fixing on 35 mm DIN-rail or fixing by screws. Green Premium compliant (RoHS/REACh).

Schneider LRD12 Thermal Overload Relay Tesys Lrd 5.5...8 A Class 10A

Request Callback

₹ 1013 / Piece Get Latest Price

Product Brochure
Current Range5.5...8 A
Poles3 Pole
Auxiliary Contact1 NO + 1 NC
Rated Voltage230 V
SeriesTeSys
Model NumberLRD32
TeSys LRD thermal overload relay, 8A/690V, thermal setting range 5.5-8A, tripping class 10A, for protection of 3-phase motors 3kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LR2K0302 Tesys K Overload Relay Cl10 0.16 0.23A

Request Callback

₹ 1430 / Piece Get Latest Price

Product Brochure
Current Rating0.5A
Current Range0.16–0.25 A
Relay MountingDIN Rail
No. of PolesTriple Pole
BrandSchneider
Model NoLR2K0302
Thermal protection adjustment range0.16…0.23 A
Thermal overload classClass 10A conforming to IEC 60947-4-1
TeSys LRK thermal overload relay, 0.23A/690V, thermal setting range 0.16-0.23A, tripping class 10A, for protection of 3-phase motors 0.06kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test slide switch for simulation of a tripping, reset/stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1K06-K16. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs/Reach).

Schneider LA9G3614 Spreaders 3P G630800 80Mm Connection

Request Callback

Get Latest Price

Product Brochure
Rated Current800 A
Part TypeConnection accessories
TypeCell Spreader
Number Of Poles3
SterilityPre-Sterilized
MaterialMetal
BrandSchneider
ReusabilitySingle Use
Length5.5 cm
ShapeL Shape
Range compatibilityTeSys LC1G TeSys LR9G
Model NoLA9G3614
Poles description3P
These accessories are straight terminal extension for TeSys Giga 630-800 contactor, 80mm wide connection. It is used to 3 Poles electrical circuit. They are screwed to the contactor terminals to increase the pitch for 80mm wide poles. The rated current is up to 800 A. It can cover -25°C to 60°C operation ambient air temperature, No derating up to 3000m altitude.

Schneider LR2K0301 Tesys K Overload Relay Cl10 0.11 0.16A

Request Callback

₹ 1430 / Piece Get Latest Price

SeriesLR2K
Motor FLC Range0.1–0.16 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRK thermal overload relay, 0.16A/690V, thermal setting range 0.11-0.16A, tripping class 10A, for protection of 3-phase motors less than 0.06kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test slide switch for simulation of a tripping, reset/stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1K06-K16. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs/Reach).

Schneider LRD03 Tesys Lrd Thermal Overload Relays 0.25...0.4 A Class 10A

Request Callback

₹ 1013 / Piece Get Latest Price

SeriesLRD
Motor FLC Range0.25–0.4 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 0.4A/690V, thermal setting range 0.25-0.4A, tripping class 10A, for protection of 3-phase motors 0.09kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD04 Tesys Lrd Thermal Overload Relays 0.4...0.63 A Class 10A

Request Callback

₹ 1013 / Piece Get Latest Price

SeriesLRD
Motor FLC Range0.4–0.63 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 0.63A/690V, thermal setting range 0.4-0.63A, tripping class 10A, for protection of 3-phase motors 0.12-0.18kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD08 Tesys Lrd Thermal Overload Relays 2.5...4 A Class 10A

Request Callback

₹ 1013 / Piece Get Latest Price

SeriesLRD
Motor FLC Range2.5–4 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 4A/690V, thermal setting range 2.5-4A, tripping class 10A, for protection of 3-phase motors 1.1-1.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD08L Tesyscl20Bimet Olr600Vac 2.54 Phase Sen

Request Callback

₹ 2252 / Piece Get Latest Price

SeriesLRD
Motor FLC Range2.5–4 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 20
Mounting TypeDIN Rail
Model NoLRD08L
TeSys LRD thermal overload relay, 4A/690V, thermal setting range 2.5-4A, tripping class 20, for protection of 3-phase motors 1.1-1.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B205 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD32 Thermal Overload Relay Tesys Lrd 23...32 A Class 10A

Request Callback

₹ 1881 / Piece Get Latest Price

SeriesLRD
Motor FLC Range23...32 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 32A/690V, thermal setting range 23-32A, tripping class 10A, for protection of 3-phase motors 15kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D25-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B205 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD3365 Tesys Lrd Thermal Overload Relays 80...104 A Class 10A

Request Callback

₹ 4910 / Piece Get Latest Price

SeriesLRD
Motor FLC Range80...104 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 104A/1000V, thermal setting range 80-104A, tripping class 10A, for protection of 3-phase motors 45kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D80-D95. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD3357 Tesys Lrd Thermal Overload Relays 37...50 A Class 10A

Request Callback

₹ 3416 / Piece Get Latest Price

SeriesLRD
Motor FLC Range37...50 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Model NoLRD3357
BrandSchneider
TeSys LRD thermal overload relay, 50A/1000V, thermal setting range 37-50A, tripping class 10A, for protection of 3-phase motors 22kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D80-D95. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LR2K0310 Tesys K Overload Relay Cl10 2.6 3.7A

Request Callback

₹ 1430 / Piece Get Latest Price

SeriesLRD
Motor FLC Range2.5–4 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRK thermal overload relay, 3.7A/690V, thermal setting range 2.6-3.7A, tripping class 10A, for protection of 3-phase motors 1.1-1.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test slide switch for simulation of a tripping, reset/stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1K06-K16. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs/Reach).

Schneider LRD380 Tesys Lrd Differential Thermal Overload Relay 6280A Class10A Everlink

Request Callback

₹ 3823 / Piece Get Latest Price

SeriesLRD
Motor FLC Range62...80A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 80A/690V, thermal setting range 62-80A, tripping class 10A, for protection of 3-phase motors 37kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by EverLink BTR screw terminals , it connects directly to the bottom terminals of 3-pole contactors LC1D40A-D80A. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD96560 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD06 Tesys Lrd Thermal Overload Relays 1...1.6 A Class 10A

Request Callback

₹ 1013 / Piece Get Latest Price

SeriesLRD
Motor FLC Range1–1.6 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 1.6A/690V, thermal setting range 1-1.6A, tripping class 10A, for protection of 3-phase motors 0.55kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider RXG22ED Interface Relay 5A 2CO Lock LED 48V DC

Request Callback

₹ 391 / Piece Get Latest Price

SeriesTesys
Current Range5 A
Relay TypeOverload
Mounting TypePlug In
Frequency50/60 Hz
Model NoRXG22ED
"This Harmony RXG plug-in relay socket has a coil control voltage of 48V DC and has 2 changeover contacts DPDT (double pole double throw) with a rating of 5A." "It has large choice of number of contacts for high rated current use with space-saving design." "It also offers a lockable test button and LED indicator." "The faston pin terminal mounts quickly and securely." "It helps to reduce the size of enclosures and increase machine reliability, you can mount nearly everywhere." "Workability for hard-wired logic automated systems to complement the functions of industrial programmable logic controllers (PLCs)." "Status display with LED, clearly signal both in the day and night.

Schneider LR9D01 Tesys Lrd Electronic Thermal Overload Relay 3P 0.1...0.5 A

Request Callback

₹ 6398 / Piece Get Latest Price

SeriesLR9
Motor FLC Range0.1–0.16 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Mounting TypeDIN Rail
Model NoLR9D01
TeSys LR9D electronic overload relay, 0.5A/690V, thermal setting range 0.1-0.5A, selectable tripping class 5-10-20-30, for protection of 3-phase motors up to 0.12kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, buttons for test, stop and reset as well as manual-automatic reset selector, dipswitches for tripping class selection, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from contactor, with use of the terminal block LAD7B205 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC), Green Premium compliant (RoHs/Reach).

Schneider LRE322 Easy Tesys Differential Thermal Overload Relay 17...25 A Class 10A

Request Callback

₹ 1982 / Piece Get Latest Price

SeriesLRD
Motor FLC Range17...25 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
The LRE relay is a differential thermal overload relays for use with fuses or magnetic circuit-breakers GV2 L and GV3 L. Its thermal setting range is 17-25A 50/60Hz and the tripping class is 10A conforming to IEC 60947-4-1. It can be direct mounted on EasyPact TVS contactors with screw clamp terminals connection. It protects unbalanced loads and motors with 11kW at 400VAC. It provides manual or automatic reset, trip auxiliary contact and flag indicator. Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach).

Schneider LRD365 Tesys Lrd Thermal Overload Relays 48...65 A Class 10A

Request Callback

₹ 3665 / Piece Get Latest Price

SeriesLRD
Motor FLC Range48...65 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 65A/690V, thermal setting range 48-65A, tripping class 10A, for protection of 3-phase motors 30kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by EverLink BTR screw terminals , it connects directly to the bottom terminals of 3-pole contactors LC1D40A-D80A. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD96560 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD083 Tesys Themral Olr 2.54.0A Cl10A Sprin

Request Callback

₹ 5589 / Piece Get Latest Price

SeriesLRD
Motor FLC Range2.5–4 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 4A/690V, thermal setting range 2.5-4A, tripping class 10A, for protection of 3-phase motors 1.1-1.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD35 Tesys Lrd Thermal Overload Relays 30...38 A Class 10A

Request Callback

₹ 1881 / Piece Get Latest Price

SeriesLRD
Motor FLC Range30...38 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 38A/690V, thermal setting range 30-38A, tripping class 10A, for protection of 3-phase motors 18.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D32-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD340 Tesys Lrd Thermal Overload Relays 30...40 A Class 10A

Request Callback

₹ 2084 / Piece Get Latest Price

SeriesLRD
Motor FLC Range30...40 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 40A/690V, thermal setting range 30-40A, tripping class 10A, for protection of 3-phase motors 18.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by EverLink BTR screw terminals , it connects directly to the bottom terminals of 3-pole contactors LC1D40A-D80A. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD96560 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD21 Thermal Overload Relay Tesys Lrd 12...18 A Class 10A

Request Callback

₹ 1170 / Piece Get Latest Price

SeriesLRD
Motor FLC Range12...18 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 18A/690V, thermal setting range 12-18A, tripping class 10A, for protection of 3-phase motors 7.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D18-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider RXG21JD Interface Relay 5A 2CO Lock 12V DC

Request Callback

₹ 346 / Piece Get Latest Price

SeriesTesys
Current Range5 A
Relay TypeOverload
Mounting TypePlug In
Frequency50/60 Hz
Model NoRXG21JD
"This Harmony RXG plug-in relay socket has a coil control voltage of 12V DC and has 2 changeover contacts DPDT (double pole double throw) with a rating of 5A." "It has large choice of number of contacts for high rated current use with space-saving design." "It also offers a lockable test button." "The faston pin terminal mounts quickly and securely." "It helps to reduce the size of enclosures and increase machine reliability, you can mount nearly everywhere." "Workability for hard-wired logic automated systems to complement the functions of industrial programmable logic controllers (PLCs).

Schneider LRD106 Tesys Lrd Thermal Overload Relays 2.5...4 A Class 10A

Request Callback

₹ 4234 / Piece Get Latest Price

SeriesLRD
Motor FLC Range2.5–4 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 6A/690V, thermal setting range 4-6A, tripping class 10A, for protection of 3-phase motors 2.2kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider RE22R2MYMR Multi relay 8A 2CO 0.1s 100h scrw 24V

Request Callback

₹ 8304 / Piece Get Latest Price

Timer TypeOn Delay
Time Range0.1–1 s
Supply Voltage24 V DC
Output Contacts2 C/O
Mounting TypeDIN Rail
Display TypeLED
Model NoRE22R2MYMR
BrandSchneider
This Harmony RE22 timing relay can be set between 0.05 seconds and 300 hours, has an output rating of 8A, is 22.5mm wide and can be supplied with 24V to 240V AC. It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail. It also offers a sealable cover, simple and precise settings with rotary trimmers. multi function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. Status display with 2 LEDs, visually inspect the status of you system without specialized tools. Diagnostic button allows simple setup and trouble shooting by non-specialists.

Schneider EOCRSS05S Electronic Overcurrent Relay 0.5..6 A 220 V Ac

Request Callback

₹ 4238 / Piece Get Latest Price

Relay TypeOverload
Relay TechnologyMicroprocessor
Current Range0.5..6 A
Mounting TypeDIN Rail
Rated Voltage220 V AC
Output Contact1 NO + 1 NC
Frequency50/60 Hz
BrandSchneider
Schneider EOCRSS05S  Electronic Overcurrent Relay  0.5..6 A  220 V Ac

Schneider EOCRSS05S  Electronic Overcurrent Relay  0.5..6 A  220 V Ac

Schneider A9C30812 impulse relay iTL 2P 2 NO 16A coil 110 VDC 230...240 VAC 50 60Hz

Request Callback

₹ 1904 / Piece Get Latest Price

SeriesTesys
Current Range16 A
ApplicationMotor
Mounting TypeDIN Rail
Poles2 Pole
Frequency50/60 Hz
Model NoA9C30812
Network typeAC
This Acti9 iTL is a modular impulse relay. This 2P device has 2 normally open contacts. Rated current is 16A, 24VAC to 250VAC operating voltage and it operates with 230VAC to 240VAC or 110VDC control voltage. Electrical endurance goes up to 200000 cycles for AC-21 or 100000 cycles for AC-22. The switching frequency is 5 switching operations/minute or 100 switching operations/day. The duration of the command order should be between 50ms to 1s. It is mainly used for lighting control applications. The Ui rated insulation voltage is 440VAC.

Schneider LRD07 Tesys Lrd Thermal Overload Relays 1.6...2.5 A Class 10A

Request Callback

₹ 1013 / Piece Get Latest Price

SeriesLRD
Motor FLC Range1.6–2.5 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 2.5A/690V, thermal setting range 1.6-2.5A, tripping class 10A, for protection of 3-phase motors 0.75kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD16 Thermal Overload Relay Tesys Lrd 9...13 A Class 10A

Request Callback

₹ 1136 / Piece Get Latest Price

SeriesLRD
Motor FLC Range9...13 A
Relay TypeThermal Overload
Auxiliary Contacts1 NO 1 NC
Model NoLRD16
BrandSchneider
Relay applicationMotor protection
TeSys LRD thermal overload relay, 13A/690V, thermal setting range 9-13A, tripping class 10A, for protection of 3-phase motors 5.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D12-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD3363 Tesys Lrd Thermal Overload Relays 63...80 A Class 10A

Request Callback

₹ 3978 / Piece Get Latest Price

SeriesLRD
Motor FLC Range63...80 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 80A/1000V, thermal setting range 63-80A, tripping class 10A, for protection of 3-phase motors 37kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D80-D95. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LR9D08 Tesys Lrd Electronic Thermal Overload Relay 3P 1.6...8 A

Request Callback

₹ 6568 / Piece Get Latest Price

SeriesLR9D
Motor FLC Range1.6- 8 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Mounting TypeDIN Rail
Model NoLR9D08
TeSys LR9D electronic overload relay, 8A/690V, thermal setting range 1.6-8A, selectable tripping class 5-10-20-30, for protection of 3-phase motors 0.75-3kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, buttons for test, stop and reset as well as manual-automatic reset selector, dipswitches for tripping class selection, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from contactor, with use of the terminal block LAD7B205 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC), Green Premium compliant (RoHs/Reach).

Schneider LRD3355 Tesys Lrd Thermal Overload Relays 30...40 A Class 10A

Request Callback

₹ 2084 / Piece Get Latest Price

SeriesLRD
Motor FLC Range30...40 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 40A/1000V, thermal setting range 30-40A, tripping class 10A, for protection of 3-phase motors 18.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector acting also as reset button, a trip test button for simulation of a tripping, a stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D80-D95. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LA7D3064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD10 Tesys Thermal Overload 4.06.0A Cl10A

Request Callback

₹ 1013 / Piece Get Latest Price

SeriesLRD
Motor FLC Range4–6 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 6A/690V, thermal setting range 4-6A, tripping class 10A, for protection of 3-phase motors 2.2kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD05L - Thermal overload relay, TeSys Deca, 690VAC, 0.63 to 1A, 1NO+1NC, class 20, screw

Request Callback

₹ 2464 / Piece Get Latest Price

SeriesLRD
Motor FLC Range0.63–1 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 20
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 1A/690V, thermal setting range 0.63-1A, tripping class 20, for protection of 3-phase motors 0.25-0.37kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B205 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LRD02 Tesys Thermal Overload 0.160.25A Cl10A

Request Callback

₹ 1013 / Piece Get Latest Price

SeriesLRD
Motor FLC Range0.16–0.25 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 0.25A/690V, thermal setting range 0.16-0.25A, tripping class 10A, for protection of 3-phase motors 0.06kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LR9D02 Tesys Lrd Electronic Thermal Overload Relay 3P 0.4...2 A

Request Callback

₹ 6568 / Piece Get Latest Price

SeriesLR9D
Motor FLC Range0.4…2 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Mounting TypeDIN Rail
Model NoLR9D02
TeSys LR9D electronic overload relay, 2A/690V, thermal setting range 0.4-2A, selectable tripping class 5-10-20-30, for protection of 3-phase motors 0.12-0.75kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, buttons for test, stop and reset as well as manual-automatic reset selector, dipswitches for tripping class selection, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from contactor, with use of the terminal block LAD7B205 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC), Green Premium compliant (RoHs/Reach).

Schneider LRD21L Tesys Lrd Thermal Overload Relays 12...18 A Class 20

Request Callback

₹ 3087 / Piece Get Latest Price

SeriesLRD
Motor FLC Range12-18 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 20
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 18A/690V, thermal setting range 12-18A, tripping class 20, for protection of 3-phase motors 7.5kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D18-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B205 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).

Schneider LR2K0305 Tesys K Overload Relay Cl10 0.54 0.8A

Request Callback

₹ 1430 / Piece Get Latest Price

SeriesLRD
Motor FLC Range0.54- 0.8A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRK thermal overload relay, 0.8A/690V, thermal setting range 0.54-0.8A, tripping class 10A, for protection of 3-phase motors 0.18kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test slide switch for simulation of a tripping, reset/stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1K06-K16. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs/Reach).

Schneider LRD05 Tesys Lrd Thermal Overload Relays 0.63...1 A Class 10A

Request Callback

₹ 1013 / Piece Get Latest Price

SeriesLRD
Motor FLC Range0.63–1 A
Relay TypeThermal Overload
Pole Configuration3 Pole
Auxiliary Contacts1 NO 1 NC
Trip ClassClass 10
Mounting TypeDIN Rail
TeSys LRD thermal overload relay, 1A/690V, thermal setting range 0.63-1A, tripping class 10A, for protection of 3-phase motors 0.25-0.37kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test selector for simulation of a tripping, reset and stop buttons, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1D09-D38. Mounting on DIN rail or screw fixing, separated from the contactor, with use of a terminal block LAD7B106 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine), Green Premium compliant (RoHs/Reach).
X

Contact Us

Govind Chauhan (Managing Director)
Electrosync Automation India Private Limited
1st Floor, 535, Patparganj Industrial Area
New Delhi - 110092, Delhi, India

Send Email
Share: